Molecular biology solution
Compact, Quick, Lightweight
DNA and RNA measuring anywhere
Previously only ever possible in laboratories, Our PCR1100 brings
mobility to genetic measuring anywhere at any time on the go.
Conventional genetic testing equipment was only used in specialized facilities as it was large-sized, expensive, and testing took a long time.
Meanwhile, there are demands for genetic testing that can be used on-site and can provide measurement results quickly.
“In order to satisfy the market needs, we developed this compact device that provides shorter testing times while maintaining a high level of accuracy by combining the following technologies held by the Information & Telecommunication Device Division of Nippon Sheet Glass Co., Ltd.
(1) “Unique small-sized fluorescence detection technology for measuring gene amount at a high sensitivity”
(2) “Technology to increase genes on a small plastic board at a high speed”
This enables you to carry out high-sensitivity genetic testing anywhere.
As the device can quickly identify various types of genes on-site, it is expected to be used in a wide range of fields including food sanitary in factories, environmental pollution investigations, and bioprospecting.
NSG Group will continue to contribute to the advancement of genetic testing in the world with its motto “faster measurement on-site”.
Item | Specifications | |
Dimension | H200 x W100 x D50mm | Excluding protrusions |
Weight | Approx. 560 g | ーー |
Power | AC 100 to 240V 50/60 Hz (incl. AC adaptor)/ DC5V3A (incl. USB power cable) | ーー |
Operating temperature range | 10 to 40°degrees Celsius | ーー |
Maximum operating altitude | 2000 m | ーー |
Number of samples | 1 | ーー |
Measurement chip (MCP1100) | 76 x 26 x 3 mm | ーー |
Volume of reaction | 15 to 20 μl | 16 μl recommended |
Excitation/fluorescent wavelength 1 | Representative wavelength 470/530 nm | Usable fluorescent dye: FAM |
Excitation/fluorescent wavelength 2 | Representative wavelength 530/630 nm | Usable fluorescent dye: ROX |
Excitation/fluorescent wavelength 3 | Representative wavelength 630/670 nm | Usable fluorescent dye: Cy5 |
Detection Channels | Maximum 3 items | ーー |
Detection format | Hydrolysis probe method | Intercalator method is not supported. |
Hot start | 40 to 99 degrees Celsius | Within 30 sec. for hot start |
Denaturation range | 40 to 99 degrees Celsius / 1 to 5 sec. | ーー |
Annealing/extension range | 40 to 75 degrees Celsius / 3 to 120 sec. | ーー |
Reverse transcription range | 40 to 75 degrees Celsius / 0 to 3600 sec. | ーー |
Maximum number of cycles | 50 cycles | ーー |
Interface | Bluetooth® (Ver.3 and later) | Can connect to PC |
Results saving function | 250 files | ーー |
Reaction conditions saving function | 15 files | ーー |
Supported OS | Windows® 7 (32bit/64bit)/Windows® 8.1 (32bit/64bit)/Windows® 10 (32bit/64bit) | ーー |
Accessories included | CD-ROM (PC software, etc.), Quick Start Manual, AC adapter, USB power cable | ーー |
Note 1: Amplification is for two temperature ranges: denaturation range and annealing/extension range. Three temperature ranges cannot be set.
Note 2: Some commercially-available PCR reagents (Master Mix) may not be used.For details, please see “Preparation of PCR reagent (Master Mix)”.
860/9, Luangpang rd., Tubyao, Ladkrabang, Bangkok, 10250, Thailand
02-050-9997 (Office)
06-2562-2369 (Office)
Email: [email protected] (inquiry)
(+66) 94-440-9900 (business)
Copyright © 2019 BioEntist Co.,Ltd. All rights reserved. Web by Mountain Studio